Brand Name : SIEMENS
Model Number : 3RW4027-1TB04
Place of Origin : CHINA
MOQ : 1PC
Price : EXW USD615-700
Payment Terms : T/T, Western Union,Paypal
Supply Ability : 100PCS Every month
Delivery Time : 60-80 work days
Packaging Details : carton
Product brand name : SIRIUS
Ambient temperature : -40 ... +80°C
Protection level : IP20
Net Weight (kg) : 0.71KG

Product Description:
SIRIUS soft starter S0 32 A, 15 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC Screw terminals Thermistor motor protection.
| General technical data | |
| product brand name | SIRIUS |
| product feature | |
| ● integrated bypass contact system | Yes |
| ● thyristors | Yes |
| product function | |
| ● intrinsic device protection | Yes |
| ● motor overload protection | Yes |
| ● evaluation of thermistor motor protection | Yes |
| ● external reset | Yes |
| ● adjustable current limitation | Yes |
| ● inside-delta circuit | No |
| product component motor brake output | No |
| insulation voltage rated value | V 600 |
| degree of pollution | 3, acc. to IEC 60947-4-2 |
| reference code according to EN 61346-2 | Q |
| reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 | G |
| Power Electronics | |
| product designation | Soft starter |
| operational current | |
| ● at 40 °C rated value | A 32 |
| ● at 50 °C rated value | A 29 |
| ● at 60 °C rated value | A 26 |
| yielded mechanical performance for 3-phase motors | |
| ● at 230 V | |
| — at standard circuit at 40 °C rated value | kW 7.5 |
| ● at 400 V | |
| — at standard circuit at 40 °C rated value | kW 15 |
| yielded mechanical performance [hp] for 3-phase AC | hp 7.5 |
| motor at 200/208 V at standard circuit at 50 °C rated | |
| value | |
| operating frequency rated value | Hz 50 ... 60 |
| relative negative tolerance of the operating frequency | -10% |
| relative positive tolerance of the operating frequency | 10% |
| operating voltage at standard circuit rated value | V 200 ... 480 |
| relative negative tolerance of the operating voltage at | -15% |
| standard circuit | |
| relative positive tolerance of the operating voltage at | 10% |
| standard circuit | |
| 10% | |
| minimum load [%] % 20 | 20% |
| adjustable motor current for motor overload | A 17 |
| protection minimum rated value | |
| continuous operating current [% of Ie] at 40 °C | 115% |
| power loss [W] at operational current at 40 °C during | W 13 |
| operation typical | |
| Control circuit/ Control | |
| type of voltage of the control supply voltage | AC/DC |
| control supply voltage frequency 1 rated value | Hz 50 |
| control supply voltage frequency 2 rated value | Hz 60 |
| relative negative tolerance of the control supply | -10% |
| voltage frequency | |
| relative positive tolerance of the control supply | 10% |
| voltage frequency | |
| control supply voltage 1 at AC | |
| ● at 50 Hz rated value | V 24 |
| ● at 60 Hz rated value | V 24 |
| relative negative tolerance of the control supply | -15% |
| voltage at AC at 50 Hz | |
| relative positive tolerance of the control supply | 10% |
| voltage at AC at 50 Hz | |
| relative negative tolerance of the control supply | -15% |
| voltage at AC at 60 Hz | |
| relative positive tolerance of the control supply | 10% |
| voltage at AC at 60 Hz | |
| control supply voltage 1 at DC rated value V 24 | -20% |
| relative negative tolerance of the control supply | |
| voltage at DC | |
| relative positive tolerance of the control supply | 20% |
| voltage at DC | |
| display version for fault signal | red |
| Mechanical data | |
| size of engine control device | S0 |
| width | mm 45 |
| height | mm 125 |
| depth | mm 155 |
| fastening method | screw and snap-on mounting |
| mounting position | With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t |
| required spacing with side-by-side mounting | |
| ● upwards | mm 60 |
| ● at the side | mm 15 |
| ● downwards | mm 40 |
| wire length maximum | m 300 |
| number of poles for main current circuit | 3 |
| Connections/ Terminals | |
| type of electrical connection | |
| ● for main current circuit | screw-type terminals |
| ● for auxiliary and control circuit | screw-type terminals |
| number of NC contacts for auxiliary contacts | 0 |
| number of NO contacts for auxiliary contacts | 2 |
| number of CO contacts for auxiliary contacts | 1 |
| type of connectable conductor cross-sections for | |
| main contacts for box terminal using the front | |
| clamping point | |
| ● solid | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 1x 10 mm² |
| ● finely stranded with core end processing | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²) |
| type of connectable conductor cross-sections at AWG | |
| cables for main contacts for box terminal | |
| ● using the front clamping point | 1x 8, 2x (16 ... 10) |
| type of connectable conductor cross-sections for | |
| auxiliary contacts | |
| ● solid | 2x (0.5 ... 2.5 mm²) |
| ● finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) |
| type of connectable conductor cross-sections at AWG | |
| cables | |
| ● for auxiliary contacts | 2x (20 ... 14) |
| ● for auxiliary contacts finely stranded with core end processing | 2x (20 ... 16) |
| Ambient conditions | |
| installation altitude at height above sea level | m 5 000 |
| environmental category | |
| ● during transport according to IEC 60721 | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
| ● during storage according to IEC 60721 | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
| ● during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| ambient temperature | |
| ● during operation | °C -25 ... +60 |
| ● during storage | °C -40 ... +80 |
| derating temperature | °C 40 |
| protection class IP on the front according to IEC 60529 | IP20 |
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
| UL/CSA ratings | |
| yielded mechanical performance [hp] for 3-phase AC motor | |
| ● at 220/230 V | |
| — at standard circuit at 50 °C rated value hp 7.5 | hp 7.5 |
| ● at 460/480 V | |
| — at standard circuit at 50 °C rated value | hp 20 |
| contact rating of auxiliary contacts according to UL | B300 / R300 |
Dimensional drawings:

|
|
3RW4027-1TB04 Siemens Sirius Soft Starter Screw Terminals Thermistor Motor Protection Images |